INTRODUCTIONS
  This UPS is specially designed for Personal computer with multi-functions.
Its light weight, compact design prefect fits to the limited working environment. The line of UPS is equipped with boost and buck AVR to stabilize input voltage range.
The main featured of UPS are listed below:
• Equipped with Boost and buck AVR to stabilize the input voltage.
• DC Start Function.
• Auto restart while AC recovery
• Compact size, Lightweight
• Protection

Installation and operation
Installing the Login UPS is as easy as following the steps shown. Be aware of the power switch must be kept in the “ON” Position, otherwise, the UPS will be disabled and your equipment will not be protected during a power failure.

Inspection
Remove the Ups from its package and inspect it for damage that may have occurred during shipping. If any damage is, discover re-pack the unit and return it to place of purchase.

Placement
Install the Ups nit in any protected environment that provides adequate airflow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Do not operate your UPS in an environment where the ambient temperature or humidity is high.
On the other hand, place the Ups unit away from the monitor at least 20 cm to avoid interference.

Charging
This unite is shipped from the factory with its internal battery fully charged, however, some charge may be lost during shipping and the battery should be recharged prior to use. Plug the unit into an appropriate power supply and allow the Ups to charge fully leaving it plugged in for at least 8 hours.

Computer connection
Connect one computer-related device into each the power receptacles supplied on the back of the UPS.

Systems Description
Front Panel

• Power Switch
• LED Indicators:
AC Mode: Green Lighting
Charge Battery: Yellow Lighting
Battery Mode: Red flashing
Silence On : yellow lighting

 
CAPACITY
650 VA
INPUT
Voltage
145-300 VAC
Frequency
50 0r 60 Hz + /5% (auto sensing)
OUTPUT
Voltage (on battery)
Simulated sine wave at Line Input +/5%
Frequency (on battery)
50 or 60 Hz +/0.5%
 
Voltage Regulation AVR
AVR automatically increase output voltage 15% Above Input Voltage if -9% to -25% of nominal, AVR decrease Output voltage 13% below input voltage of +9% to +25% normal
PROTECTION AND FILTRIING
Overload Protection
UPS automatic shutdown if overload exceed and 110% of nominal at 60 second and 130% at 3 FILTRINGseconds

Unit Input
Fuse for overload & short circuit protection

 

Short Circuit
UPS output cut off immediately or input fuse protection
BATTERY Type Sealed, maintenance-free acid
  Typical Recharge Time 4 Hours (to) 90% of full capacity
Protection Automatic self-test & descharge protection, replace, battery indicator

 

Back up Time 10-25 Minutes (depending on computer load)
ALARM Battery Back-up Slow beeping sound (about 0.47 Hz)
  Battery Low Rapid beeping sound (about 1.82 Hz)
  Overload Continue beeping sound
ENVIRONMENT Audible noise <40 dBA (1 meter from surface)
  Storage Condition 15000 meters max elevation

 